home *** CD-ROM | disk | FTP | other *** search
/ Cream of the Crop 26 / Cream of the Crop 26.iso / math / panel45.zip / PANEL4.DO_ / PANEL4.DO
Text File  |  1997-05-24  |  19KB  |  429 lines

  1.  
  2. I N T R O D U C T I O N  
  3.  
  4. Electrical Design Software is a small software company located in southern New Hampshire that
  5. was established in 1992.  Our mission is to produce quality software, at a reasonable price for the 
  6. electrical industry.  We unconditionally guarantee your satisfaction with any of our products.  If
  7. you are not completely satisfied, you can return the software within 90 days for a full refund.
  8.  
  9. Support for all software is free.  Not for 60 days or one year but as long as you use our products. 
  10. However, you will find the applications very easy to use.  Each program has a logical flow.  In
  11. fact with little computer experience you will quickly be productive.   Future programs and updates
  12. to the existing ones will be developed for Windows 95 and NT-3.51 or the latest Windows
  13. environment at the time of development.  All code related software will be updated on each code
  14. cycle (every 3 years). 
  15.  
  16. If you have a modem, you can download a demo version from many of the online services such as
  17. CompuServe, America Online, Delphi, Exec-PC, Connect America, Public Software Library and
  18. many others.  For example to find Panel 4.5 on CompuServe, do a file name search on "Panel". 
  19. All the files named panel will display.  Look for the one "Panel 4.5 Circuit directory inserts" From
  20. there you can download "Panel.Zip".  With a 28K modem it will take about 20 minutes.  Once
  21. you unzip the file simply start setup to install. 
  22.  
  23. Electrical Design Software E-mail   105102.3663@compuserve.com
  24.  
  25. Thank you for your interest in Electrical Design Software.  We are committed to serving the
  26. electrical industry.  We will continue to work hard to become a  company crafted by the needs
  27. and demands of those in the electrical industry.
  28.  
  29. Sincerely,   Brian Lamoureux,   Software Development.
  30.  
  31.  
  32.  
  33. WHAT IS PANEL - VERSION 4.5
  34.  
  35. Panel will create and print custom circuit directories that will insert into the cover or display area
  36. of any panel, switchboard, motor control center or any electrical distribution system.
  37.  
  38. SAFETY:  Increase safety, efficiency and professionalism with a well formatted  and organized
  39. system of circuit identification.  
  40.  
  41. DATABASE:  A complete database system that will store the circuit directory and panel information
  42. as one record.  
  43.  
  44. INFORMATION: Panel 4.5 will store information such as, each circuit item, circuit number, breaker
  45. size, panel name, location, amps, volts, phase, wire, main breaker or fuse size, mounting, ground
  46. information,  conductor,  raceway, manufacturer,  breaker type, rms-aic rating,  customer or building
  47. information,   prepared by information, headers,  footer and a special notes section. 
  48.  
  49. ADVERTISEMENT: The headers or footer section is the perfect place to put your company phone
  50. numbers, emergency number,  logo or other contact instructions.
  51.  
  52. SPECIAL INSTRUCTIONS:  A header or footer is the perfect place for reminder instructions when
  53. de-energizing a circuit or other procedure related information.
  54.  
  55. PRINTED DIRECTORIES:  Print various types and sizes of directories such as standard or single
  56. column format.  Directories are in a very  attractive boxed style. Each printed directory is constructed
  57. based on the data entered.
  58.  
  59. If data at the head of the directory is not entered, the directory is built with a smaller top section. 
  60. Each directory is a customized version of the data entered. Each panel is a  record stored in the data
  61. file.  Records are later found using three indexes.  Customer name, Panel name or Panel location.
  62. Panel will store as many panels as disk space will allow.  (100,000 panels or more). All fields are
  63. completely defined by you.  Any circuit numbering format is set by you.
  64.  
  65. Each directory is built to the size that is placed in the circuits field. Panel will print large or small
  66. directories choose the size best suited for each project. Print standard directories or single column
  67. directories for single row panels. Print a field form that is used to gather field data. Improve customer
  68. relations for your company by maintaining a circuit directory program as a service. Offer customers
  69. free circuit directory printing 
  70.  
  71. INCREASING SAFETY IS THE SINGLE MOST IMPORTANT REASON TO USE A CIRCUIT
  72. IDENTIFICATION SYSTEM.  
  73.  
  74.  
  75. SYSTEM REQUIREMENTS 
  76. Your personal should meet (or exceed) the following: 
  77.  
  78. * 486 CPU, 100Mhz clock speed
  79. * WIN 95, Windows NT 3.51 or later
  80. * 8MB RAM, 16MB recommended
  81. * 12MB free hard disk space
  82.  
  83.  
  84. "This program is produced by a member of the Association
  85. of Shareware Professionals (ASP).  ASP wants to make sure
  86. that the shareware principle works for you. If you are
  87. unable to resolve a shareware-related problem with an ASP
  88. member by contacting the member directly, ASP may be able
  89. to help. The ASP Ombudsman can help you resolve a dispute
  90. or problem with an ASP member, but does not provide
  91. technical support for members' products. Please write to
  92. the ASP Ombudsman at 545 Grover Road, Muskegon, MI
  93. 49442-9427 USA, FAX 616-788-2765 or send a Compuserve
  94. message via CompuServe Mail to ASP Ombudsman 70007,3536"
  95.  
  96.  
  97. CONVERT VERSION 2X DATA  TO 4.X FORMAT:
  98.  
  99. This utility is for users of Panel 2.0 or 2.1 for DOS.  The utility will take the file "Panel.Mdb" extract
  100. each record from the DOS database file and display a selection box to import the desired records into
  101. Panel 4.x.
  102.  
  103. When installing Panel for Windows, it is recommended to install into the same directory as the
  104. DOS version OR copy the DOS database file "Panel.Mdb" into the Panel 4.5 folder.  The reason is
  105. the version 2x database file Panel.Mdb must be in the same directory as Panel 4.5 to import 2x data
  106. into 4.x
  107.  
  108.  
  109. TRIAL USE (SHAREWARE EVALUATION VERSION) WARRANTY:
  110.  
  111. The Shareware evaluation (trial use) version is provided AS IS.  Electrical Design Software MAKES
  112. NO WARRANTY OF ANY KIND, EXPRESSED OR  IMPLIED, INCLUDING WITHOUT
  113. LIMITATION, ANY WARRANTIES OF  MERCHANTABILITY AND/OR FITNESS FOR A
  114. PARTICULAR PURPOSE.
  115.  
  116.  
  117. REGISTERED VERSION ONLY WARRANTY:
  118.  
  119. LIMITED WARRANTY. Electrical Design Software warrants that (a) the software product will
  120. preform substantially in accordance with the accompanying help materials for a period of ninety (90)
  121. days from the date of receipt.
  122.  
  123. CUSTOMER REMEDIES. Electrical Design Software and its suppliers, entire liability and your
  124. exclusive remedy shall be at Electrical Design Software's option, either (a) return of the price paid,
  125. if any, or (b) repair or replacement of the SOFTWARE PRODUCT that does not meet Electrical
  126. Design Software's Limited Warranty and which is returned to Electrical Design Software with a copy
  127. of your receipt.  This limited warranty is void if failure of the SOFTWARE PRODUCT has resulted
  128. from  accident, abuse or misapplication.  Any replacement SOFTWARE PRODUCT will be
  129. warranted for the remainder of  the original warranty period or (30) days whichever is longer. 
  130. Outside the United States, neither these remedies nor any product support services offered by
  131. Electrical Design Software are available without proof of purchase from an authorized international
  132. source.
  133.  
  134. NO OTHER WARRANTIES.  TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE
  135. LAW, ELECTRICAL DESIGN SOFTWARE AND ITS SUPPLIERS DISCLAIM ALL OTHER
  136. WARRANTIES AND CONDITIONS, EITHER EXPRESSED OR IMPLIED, INCLUDED BUT
  137. NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
  138. PARTICULAR PURPOSE, TITLE, AND NONINFRINGEMENT, WITH REGARD TO THE
  139. SOFTWARE PRODUCT, AND THE PROVISIONS OF OR FAILURE TO PROVIDE SUPPORT
  140. SERVICES. 
  141.  
  142. LIMITATION OF LIABILITY.  TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE
  143. LAW, IN NO EVENT SHALL ELECTRICAL DESIGN SOFTWARE OR ITS SUPPLIERS BE
  144. LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES
  145. WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF
  146. BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
  147. ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE OF OR INABILITY TO USE
  148. THE SOFTWARE PRODUCT OR THE PROVISION OF OR FAILURE TO PROVIDE SUPPORT
  149. SERVICES, EVEN IF ELECTRICAL DESIGN SOFTWARE HAS BEEN ADVISED OF THE
  150. POSSIBILITY OF SUCH DAMAGES.  IN ANY CASE (ELECTRICAL DESIGN SOFTWARE)
  151. ENTIRE LIABILITY UNDER ANY PROVISION OF THIS EULA SHALL BE LIMITED TO
  152. THE GREATER OF THE AMOUNT ACTUALLY PAID BY YOU FOR THE SOFTWARE
  153. PRODUCT OR U.S. $5.00:
  154.  
  155.  
  156. QUICK INSERT:
  157.  
  158. Use the quick insert feature by double clicking on the selected field or the description frame to quick
  159. insert predefined text into the circuit description, circuit size, prepared for, prepared by, headers and
  160. footer fields.  The text is defined in the quick insert window that is accessible from the top tool bar
  161. icon.  The bottom status bar will display the text that will paste into the description or size field when
  162. doubled clicked with the left mouse button 
  163.  
  164. The quick insert screen has four main sections:
  165.  
  166. 1. The description and size section.  This section has twenty one fields to define text that would be
  167. typed often.  for example "General outlets" , "Lighting circuit for room ??" or even the (""  double
  168. quotes) to put under 2 or 3 pole breakers.
  169.  
  170. TO INSERT DATA INTO THE DESCRIPTION AND SIZE FIELDS:
  171. 1. Make visible the quick insert window by clicking the icon in the top tool bar.
  172. 2. Enter the text using up to 21 fields.
  173. 3. Select the field by clicking with the mouse or close the window with the cursor on selected text.
  174. 4. The selected text will display at the bottom status bar of the main window.
  175. 5. Double click on any description or size field to insert the selected text.
  176.  
  177. TO INSERT DATA INTO THE PREPARED FOR, PREPARED BY OR HEADER FIELDS:
  178. 1. Make visible the quick insert window by clicking the icon in the top tool bar.
  179. 2. Enter the default text in the prepared for, prepared by, header and footer fields.
  180. 3. Double click on the frame (not the field itself) to insert the text.
  181.  
  182. For example; Enter your company name, address, city, state and zip in the prepared by box of the
  183. quick insert window.  Next create a new record by clicking the add new icon on the top tool bar. 
  184. With the mouse double click on the frame (click where is says "Prepared By").  This action will take
  185. the text typed into the prepared by box of the quick insert window and place it into the current
  186. record.  It's that simple.  
  187.  
  188.  
  189. GRID DISPLAY:
  190.  
  191. With the grid display multiple records are quickly analyzed.  The button in the "Prepared for Name
  192. field will send a record to the printer for a quick print using the default directory style.
  193.  
  194. Data in the grid can be changed.  When a change has occurred a pencil will display at the left column. 
  195. When a move to another record occurs the new data will write to disk.
  196.  
  197.  
  198. PRINT DEFAULT DIRECTORY:
  199.  
  200. Use the Print default directory to: define a directory to print when printing from the grid window. 
  201. The available directories are 8, 9 or 10 font boxed style.  
  202.  
  203. Once a directory type is selected, clicking the button at the right of the prepared for name field will
  204. automatically send the directory to the default Windows printer.  This feature allows a very quick
  205. method of printing various multiple directories.
  206.  
  207.  
  208. PRINT OPTIONS:
  209.  
  210. Select destination, and type of report.
  211. To Produce a report:
  212.  
  213. 1. Select to send the report to the printer or a window.
  214. 2. Place a check mark by the type of report to produce.  
  215. 3. Press the send command button.
  216.  
  217. When multiple reports are selected with the window as the destination a separate window is created
  218. for each report.
  219.  
  220.  
  221. INSERT A NUMBER IN THE SIZE FIELDS:
  222.  
  223. Select this feature to quickly insert a number in all the size fields.  Example: many lighting panels are
  224. filled with 20 amp single pole breakers.  This utility will save the trouble of typing 20 in the size fields
  225. for 42 fields.
  226.  
  227.  
  228. COPY THIS RECORD TO A NEW RECORD:
  229.  
  230. A time saving command that will copy the prepared for,  prepared by, header and footer information
  231. of the current record into a newly created record.
  232.  
  233.  
  234. DATABASE FILE REPAIR OR COMPACT:
  235.  
  236. A repair utility that can be used to repair a database file that may have been damaged, such as loss
  237. of power that occurred during a database read or write operation.  A Compaction utility can be used to compact a database file.  When a record is deleted it is removed from view, however the disk space used by the deleted record is still part of the database file.  The compaction utility recreates the database file with valid records only thus saving disk space.
  238.  
  239.  
  240. PREPARED FOR NAME:
  241.  
  242. The Prepared for Name field is an indexed field.  When the index is set on the Prepared for Name the
  243. records will be sorted in ascending order based on the information in the Name field. The prepared
  244. for information can be used in two ways.  When used by an electrical contracting firm the customer
  245. information such as name address etc. In the case of a large facilities this could be  a building name
  246. or number, a floor or any format that is appropriate.
  247.  
  248.  
  249. PANEL NAME:
  250.  
  251. The Panel Name field is an indexed field.  When the index is set on the Panel Name the records will
  252. be sorted in ascending order based on the information in the Panel Name field. This field will hold up
  253. to 40 characters. A double description is easily achieved. 
  254.  
  255. (Ex: HVLP-3  Third floor Lighting)
  256.  
  257.  
  258. PANEL LOCATION:
  259.  
  260. The Panel Location field is an indexed field.  When the index is set on the Panel Location records will
  261. be sorted in ascending order based on the information in the Panel Location field. This field will hold
  262. up to 40 characters.  This type of information is mainly useful when analyzing panel information from
  263. the office.
  264.  
  265.  
  266. PANEL AMPS:
  267.  
  268. Information about the ampere rating of the panel.  In some cases this may be different than the
  269. ampere rating of the main breaker or fuses. An example would be a panel ampere rating of 400 with
  270. a main breaker size of 250.
  271.  
  272.  
  273. PANEL VOLTS:
  274.  
  275. Voltage the panel is operating at.  Some typical systems are 120/240, 208Y/120, 240, 480Y/277, 600 
  276.  
  277.  
  278. PHASE:
  279.  
  280. Phase of the system.  Generally 1 or 3.
  281.  
  282.  
  283. WIRE:
  284.  
  285. Information about the electrical system.  Generally 3 or 4 wire systems.
  286.  
  287.  
  288. CIRCUITS:
  289.  
  290. The circuits field defines the size of the directory that will be created.  A value of 42 is the maximum
  291. value this field can accept.  A entry in the circuits field is required to produce a report.
  292.  
  293.  
  294. CIRCUIT  #, DESCRIPTION & SIZE:
  295.  
  296. The circuit number field can accept any numbering format that is used and will hold two characters.
  297. The description field will hold up to thirty characters. The size field will hold up to eight characters.
  298.  
  299.  
  300. PREPARED BY NAME:
  301.  
  302. Prepared by information will print at the top right of the circuit directory.  
  303.  
  304.  
  305. RACEWAY:
  306.  
  307. Information about the raceway feeding the panel.   This may be a pipe size or a cable type. 
  308.  
  309.  
  310. CONDUCTOR SIZE & TYPE:
  311.  
  312. Information about the conductors, or cable feeding the panel.  Ex: #2 Cu THHN
  313.  
  314.  
  315. FED FROM LOCATION:
  316.  
  317. Information about where the panel is fed from.  This could be another panel in a different electric
  318. room (Ex: Panel HVDP3 Rm 227) or for a single family dwelling it could be (Ex: Outside meter).  
  319.  
  320.  
  321. BREAKER TYPE:
  322.  
  323. Plug in OR bolt on type circuit breaker or any special characteristic about the breakers such as, shunt
  324. trip, frame size, Solid state, Manufacturer catalog number,  AC or DC rated, Heavy duty, Normal
  325. duty, Current limiting, Surge arrestor, SWD or any information. 
  326.  
  327.  
  328. MANUFACTURER:
  329.  
  330. Information about the manufacturer of the panel.  This becomes useful when examining the panel
  331. characteristics at the computer.  
  332.  
  333.  
  334. RMS, AIC RATING:
  335.  
  336. RMS, AIC rating of the circuit breakers or fuses.  The current interrupting rating is expressed in rms
  337. symmetrical amperes.  It is the maximum current the breaker can be expected to safely interrupt.  UL
  338. requires all circuit breakers to be so marked with their proper ratings.  Some typical UL interrupting
  339. ratings for molded case circuit breakers (120 to 600 volts) are 10,000 - 14,000 - 18,000 - 22,000 -
  340. 25,000 - 30,000 - 35,000 - 42,000 - 50,000 - 65,000 - 100,000 - 150,000 - 200,000.  
  341.  
  342.  
  343. MOUNTING METHOD:
  344.  
  345. Mounting method used such as surface or flush.  Other useful information with respect to the
  346. mounting method is the location of exit on the panel.  For example a line such as (Flush - top exit
  347. only).  If more space is required than the field has available, a short form such as (Flush - t exit only)
  348. could be used.  In addition each record has two headers and one footer that could be used as a legend
  349. of abbreviations.  Ex: t exit only = conduits or cables can connect on the top of the panel only.
  350.  
  351.  
  352. MAIN BREAKER OR FUSE SIZE:
  353.  
  354. Ampere rating of the main breaker OR fuses.  In some cases this may be different than the ampere
  355. rating of the panel. An example would be a panel ampere rating of 400 amps with a main breaker size
  356. of 250 amps.
  357.  
  358.  
  359. GROUNDING INFORMATION:
  360.  
  361. Information about the panel grounding such as wire type, size, or method.
  362.  
  363.  
  364. NOTES FOR THIS RECORD:
  365.  
  366. Any information.  This is for the benefit of the circuit directory designer.  The notes information will
  367. not print on any reports.  This is the only location that information can be stored that will not print
  368. on a report.
  369.  
  370.  
  371. HEADER - FOOTER:
  372.  
  373. List information that you want printed at the top of a circuit directory with the header fields or at the
  374. bottom for the footer field. 
  375.  
  376.  This could be:
  377. 1. Instructions to follow when making changes in the directory.  
  378. 2. Instructions to follow when de-energizing a circuit.  
  379. 3. Emergency information or instructions.
  380. 4. Advertising for your company.
  381. 5. Circuit information for a sub main breaker.
  382.  
  383.  
  384. PRINTED DIRECTORIES: 
  385.  
  386. Directories can be printed in:
  387. * Boxed style small font
  388. * Boxed style large font
  389. * Single column format
  390. * Quick listing of all records
  391. * Field form numbered
  392. * Field form no-numbers
  393. * Field Form
  394.  
  395.  
  396. SELECT AN INDEX:
  397.  
  398. Records are displayed in ascending order based on the current index. Panel has three indexes. The
  399. default index is the Prepared for Name index.  If the index is changed the index on the next session
  400. will be the index that the application terminated with.
  401.  
  402. The indexes are:
  403. 1. Prepared for Name
  404. 2. Panel Name
  405. 3. Panel Location
  406.  
  407.  
  408. CIRCUIT NUMBERS:
  409.  
  410. Time saving commands. Clear circuit numbers will clear all fields to allow a custom numbering
  411. scheme.  Circuit numbers 1 - 42 will place numbers 1 thru 42 this is the most common format. Circuit
  412. numbers 43 - 84 will place numbers 43 thru 84.  Single column will start on the left and number 1 thru
  413. 21 on the left and 22 thru 42 on the right.
  414.  
  415.  
  416. OBTAINING TECHNICAL SUPPORT:
  417.  
  418. Technical support is free.  Four methods of support are available. E-mail, Fax, Phone, Mail
  419. The preferred method is to E-mail or Fax.
  420.  
  421. 1.   E-mail    105102.3663@compuserve.com OR Internet  internet:105102.3663@compuserve.com
  422.  
  423. 2.   Fax. Call 1-603-893-9008 
  424.  
  425. 3.   Phone.    Call 1-603-893-9008  Monday thru Friday  5 to 8 PM.
  426.  
  427. 4.   Mail.     Electrical Design Software  12 Vassar Drive  Pelham, NH 03076
  428.  
  429.